        多槽手動超聲波清洗機的使用方法如下:
        The usage method of the multi slot manual ultrasonic cleaning machine is as follows:
        將發生器與清洗槽連接電纜接好。
        Connect the cable connecting the generator to the cleaning tank.
        將槽內注入選用的清洗液。
        Inject the selected cleaning solution into the tank.
        將發生器接入220V±10% 50赫茲交流電源。
        Connect the generator to a 220V ± 10% 50Hz AC power supply.
        打開發生器電源開關,電源指示燈亮(此時槽內液體開始振動空化)。
        Turn on the power switch of the generator, and the power indicator light will be on (at this point, the liquid in the tank will start to vibrate and cavitate).
        使用多槽手動超聲波清洗機時,應注意事項包括:
        When using a multi slot manual ultrasonic cleaning machine, precautions include:
        設備必須放在通風、干燥的區域,發生器后側的風扇孔應定期清潔。發生器四面留有通風口,以使氣流暢通無阻。
        The equipment must be placed in a ventilated and dry area, and the fan holes behind the generator should be cleaned regularly. There are ventilation openings on all sides of the generator to ensure smooth airflow.
        超聲波清洗槽必須放入液體后才能開機工作,低水位高度>100mm(底振式)且水平放置,換能器在側面時,為清洗槽槽沿100mm處,如在空氣狀態開機會損壞機器。
        The ultrasonic cleaning tank must be filled with liquid before starting up and working. The low water level height is greater than 100mm (bottom vibration type) and placed horizontally. When the transducer is on the si
        de, it is necessary to clean the tank along the 100mm edge. If starting up in air, it will damage the machine.
        多槽手動超聲波清洗機
        當清洗缸體溫度為常溫時,切勿將高溫液體直接注入缸內,以免導致換能器松動而影響機器正常使用。
        When the cleaning temperature of the cylinder block is at room temperature, do not directly inject high-temperature liquid into the cylinder to avoid loosening the transducer and affecting the normal use of the machine.
        定期檢查換能器,切勿使其變潮及撞擊,以免造成不必要的損失。使用完畢后,應關閉總電源。關機后不要立刻重新開機,間隙時間應在1分鐘以上。
        Regularly inspect the transducer and do not let it become damp or collide to avoid unnecessary losses. After use, the main power should be turned off. Do not restart immediately after shutting down, the gap time should be at least 1 minute.
        以上是使用多槽手動超聲波清洗機的步驟和注意事項,供您參考,建議根據實際情況加以調整。
        The above are the steps and precautions for using a multi slot manual ultrasonic cleaning machine for your reference. It is recommended to make adjustments according to the actual situation.

        聯系我們

        詹老師:18663767799(微信同號)

        陶老師:13011716033(微信同號)

        張老師:18663767790(微信同號)

        :1476171179/1500705758

        :jnkergs@163.com

        :地址:山東省濟南市濟陽區創業路與啟航街交叉口南40米

        關注科爾

        • 掃一掃了解更多

        • 掃一掃了解更多

        備案號:魯ICP備18049717號-1  魯公網安備37011202000628號
      2. <sub id="h3v49"><address id="h3v49"><nobr id="h3v49"></nobr></address></sub>

        <nav id="h3v49"><address id="h3v49"><meter id="h3v49"></meter></address></nav>

            <nav id="h3v49"><listing id="h3v49"></listing></nav>

            <form id="h3v49"></form>
          1. 每天将为您更新半岛少妇写真福利视频